Cooling Towers: 500-Ton
How Our 500-Ton Cooling Tower Works
Our 500-ton cooling tower system operates with four main components:
Tower
Fan
Recirculating pump
Fill material
A machine’s system generates excess heat, and the cooling tower utilizes water to remove the hot air and cool it through evaporation.
Water enters the process system and travels over the tower, past the air, creating the evaporative cooling effect. The heat effectively moves from the water into the air, where it generates rising temperatures and humidity.
The water cools from the evaporation, and then the recirculating pump drives the cooled water back to the process system, where the cycle continues.
Benefits of a 500-Ton Cooling Tower
Gain several benefits when you rent a 500-ton cooling tower from Temperature Control Rental Solutions, including:
Accurate temperature control: This unit offers precise temperature control that maximizes efficiency and promotes energy savings.
Mobility: You can utilize a forklift, crane or trailer to transport the 500-ton cooling tower to your desired location.
Low maintenance: One of the most significant advantages of renting a 500-ton cooling tower from TCRS is its minimal maintenance requirements to keep the unit operating at peak performance.
Straightforward installation: Another benefit of this unit is its easy installation process, meaning you can implement new temperature control equipment without causing major disruptions or downtime for your operation.
Rental advantages: When you opt to rent a cooling tower from TCRS, you can save on operating costs and benefit from our 24/7 emergency solutions.
Common Applications
The 500-ton cooling tower might be the ideal solution for light industrial applications. The following are some key equipment specifications to note:
Dimensions: The unit measures 23 feet and 5 inches long. It is 7 feet and 11 inches wide and has a height of 9 feet and 11 inches.
Flow temperature: The 500-ton cooling tower has a maximum inlet temperature of 95 degrees Fahrenheit and an outlet temperature of 78 degrees Fahrenheit.
Rigging: This cooling tower features high point pick points and fork slots in the basin for simple transportation processes.
Weight: The shipping and rigging weight for this unit is 8,500 pounds, and its operating weight is 15,950 pounds.
Piping: You can find a 2-inch-by-6-inch inlet connection and a 2-inch-by-10-inch outlet connection on this unit.
Typical applications for our 500-ton cooling tower include the following:
Containment and spent fuel pool cooling
Jacketed reactor cooling
Scrubber cooling
Supplemental cooling tower water
Chiller condenser water
Technical Data
Design |
Induced draft, counterflow cooling tower |
Flow Temperature |
1500 gpm (750 gpm minimum -2500 gpm maximum 95°F inlet,85° outlet @ 78° FWB Maximum inlet temperature 125°F |
Electrical |
460 / 30 / 60 hertz 54 FLA |
Fans |
2 X 25 HP Internally mounted with a shaft drive coupled to the fan gearbox |
Make Up Water |
2 X 2" MPT coupled to a brass float valve with adjustable plastic float |
Blowdown & Drain |
2 X 3" FPT |
Fill Material |
Hybrid Polyvinyl Chloride (HPVC) Fill is self-extinguishing for fire resistance with a flame spread of 5 under A.S.T.M. designation E-84-81a |
Piping |
2 X 6" inlet connections 2 x 10" outlet connections |
Rigging |
High point pick points Fork slots in basin |
Dimensions |
23'5" Long x 7'11" Wide x 9'11" High |
Weights |
8,500 lbs. Shipping and Rigging 15,950 lbs. Operating |
Contact Us to Learn More About Our 500-Ton Cooling Towers
When you need a reliable and high-performing cooling tower, turn to Temperature Control Rental Solutions for high-quality solutions and responsive service.
If you have any questions or are interested in a rental quote for the 500-ton cooling from TCRS, contact us today.